66kV变电站31500kVA主变压器节能降耗改造
Energy saving reconstruction research of 31500 kVA main transformer in 66 kv substation
李红军
东北轻合金有限责任公司
- 摘 要
- 通过对新型节能SZF10、31500kVA有载调压变压器的技术研究和公司主降压老式变压器改造方案论证,成功的实施了节能改造,为我公司主降压变电所的可靠运行、节能降耗、输出电压稳定提供了保证。
- 关键词
- SZF10有载调压变压器;节能;降耗
- 分类号
- TM406;TM63
- 栏 目
- 实用技术
- 出 处
- 《冶金与材料》2014年第3期,第 28-30 页(共 3 页)
- 出版日期
- 2014-06-15
- 知网数据
- 下载 55 次(截至 2026-09-29)
- Abstract
- Based on the technology research of the new energy- saving on- load voltage regulating transformer of SZF10,31500 kVA and the argument of the main step- down old transformer reconstruction scheme,the successful implementation of the energy saving renovation was carried out,so as to provide the guarantee for the reliable operation of my company's main step- down substation,saving energy,reducing consumption,and output voltage stability.
- Keywords
- on-load voltage regulating transformer; energy-saving; reducing consumption